Ordering details | |
---|---|
Product type description | BDF200-ST1-AS-NHK-LMRD-LTWH-LTGN |
Article number | 101215277 |
EAN Code | |
eCl@ss | 27-37-12-02 |
Approval | |
Approval | TÜV USA/CAN AS-i |
Classification | |
Standards | EN ISO 13849-1, IEC 61508 |
PL | up e |
Control category | up 4 |
PFH value | 1.4 x 10−8 /h |
- notice | up to max. 5.000 switching cycles/year |
SIL | up 3 |
Mission time | 20 Years |
Global Properties | |
Permanent light | BDF200AS (Vorzugstypen) |
Standards | EN 60947-5-1, EN ISO 13850, EN ISO 13849-1, IEC 61508, EN 50295 |
Climatic stress | to DIN EN 60068 |
Material of the housings | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Weight | 280 |
Positions used | |
- Position 01 | Emergency stop latching pushbutton, with Protective collar |
- Position 02 | Illuminated signal, red |
- Position 03 | Illuminated pushbutton, White |
- Position 04 | Illuminated pushbutton, green |
Response time | <> |
Mechanical data | |
Design of electrical connection | connector plug M12, 4-pole, bottom |
Mechanical life | |
- Emergency-Stop button | 100.000 operations |
- Command devices | 1.000.000 operations |
restistance to shock | 15 g / 11 ms |
Resistance to vibration | 10 … 150 HZ, Amplitude 0,35 mm / 5 g |
Indicator lamp (Y/N) | No |
Ambient conditions | |
Ambient temperature | |
- Min. environmental temperature | −25 |
- Max. environmental temperature | +65 |
Storage and transport temperature | |
- Min. Storage and transport temperature | −25 |
- Max. Storage and transport temperature | +85 |
Protection class | IP65 |
Protection rating | II, Double-insulated |
Overvoltage category | III |
Degree of pollution | 3 |
Electrical data - AS interface | |
AS-i Supply voltage | 18 … 31.6 VDC, Protection against polarity reversal |
- Min. supply voltage | 18 |
- Max. supply voltage | 31.6 |
AS-i operating current | ≤ 150 |
- AS electronics | |
- Total | |
AS-i Device insulation | internally short-circuit proof |
AS-i Specification | Safety Slave |
- version | V 3.0 |
- Profile | S-7.B.F.F |
AS-i Inputs | |
- Channel 1 | Data bits DI 0/DI 1= dynamic code transmission |
- Channel 2 |